Scientific Tool

LC Gradient Designer

Create optimized liquid chromatography gradient profiles using the Linear Solvent Strength model. This easy-to-use web tool simplifies gradient design, providing reproducible parameters and deeper insight into gradient behavior. Generate and copy a formatted gradient table instantly—no login or data storage required.

System Parameters

Column Dead Volume (Vm):1.13 mL
How To Determine This Value?
Advanced Parameters

These values enable additional validation warnings and calculations to help optimize your gradient method.

How To Determine This Value?
How To Determine This Value?

Gradient Steps

Total Run Time: 0.00 min
How to use this table

Adding steps: Use the buttons below the table to add Isocratic Hold, Gradient Ramp, or Step Change segments.

Edit Values: Each row has an "Edit Values" dropdown that determines which parameters are user-defined versus calculated automatically.

Columns: F = Flow rate (mL/min), Binit/Bfinal = Initial/final %B, tG = Duration (min), nVm = Column volumes, k*S = Gradient steepness parameter.

Editing cells: Click any white cell to edit. Gray cells are calculated based on your Edit Values selection. Calculations are dynamic.

Deleting: Click the trash icon on any row.

#
Label
Type
Edit Values
F
Binit
Bfinal
tG
nVm
k*S
Start
End

No gradient steps defined.

Click one of the buttons below to add a step.

mL/min

Gradient Profile

0%25%50%75%100%%B0.02.04.06.08.010.0Time (min)

Metadata

Cycle Time: 0.50 min

Time 'on-column' for full injection slug: 6.6 Seconds

Total Equilibration Column Volumes (with injection cycle): 0.00

Export Gradient Table

Copy the gradient data to paste into spreadsheets or instrument software.

Preview (Full Table)

# LC Gradient Designer Export
# Generated: 2026-02-02T14:10:31.567Z
#
# System Parameters:
# Column: 10 cm x 4.6 mm ID
# Particle Type: Fully Porous
# Flow Rate: 1 mL/min
# Vm (calculated): 1.13 mL
# Total Run Time: 0.00 min
#
Step	Label	Type	B_init (%)	B_final (%)	tG (min)	Start (min)	End (min)	nVm	k*S

Usage Tips

  • Full Table: Complete data including all calculated values. Paste into Excel or Google Sheets.
  • Time/%B Only: Simplified format for instrument gradient tables. Contains just the time and %B columns.
  • • Lines starting with # are comments and may be ignored by instruments.

Need Help or Have Ideas to Improve This Tool?

Harman Solutions wants to hear your feedback and can help you simplify your analytical chemistry.

Get in Touch